Tel : +86-591-86397381
Email : sale@hosempower.com
Skype : +86-13205904365
The 500kVA Diesel Generator, powered by the reliable Cummins QSZ13-G3 engine and paired with a Stamford HCI 544 C alternator, delivers a consistent 500kVA output. This powerhouse generator is an effective solution to power disruptions, providing dependable, continuous energy to keep your operations running smoothly during electricity outages. Ideal for industrial and commercial applications, it ensures reliability and peace of mind in critical situations.
The 500kVA Diesel Generator, powered by the robust Dongfeng Cummins engine model QSZ13-G3, is equipped with an ECU fuel injection system for precise fuel management and optimal performance. Its turbocharged and charge air-cooled aspiration system provides enhanced power output, while its design meets STAGE II emission standards, making it both efficient and environmentally compliant. Ideal for high-demand applications, this generator offers reliable, heavy-duty performance suitable for various industrial and commercial power needs.
Generator Set Specification | ||
Model | A-C500 | |
Max. Power | kVA | N.A. |
kW | N.A. | |
Rate Power | kVA | 500 |
kW | 400 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 721.7 |
Fuel Tank Capacity | L | 800 |
Dimension For Open-type Genset | mm | 3300 X 1100 X 1650 |
Weight For Open-type Genset | kg | 3400 |
Dimension For Soundproof Genset | mm | 4350 X 1450 X 2180 |
Weight For Soundproof Generator | kg | 4020 |
Noise Level for Soundproof Generator at 7M | dBA | 80 |
Battery | Two of Free Maintenance Battery |
Engine Specification | ||
Engine Manufacturer | Dongfeng Cummins Engine Co., Ltd. | |
Engine Brand | Cummins | |
Engine Model | QSZ13-G3 | |
No. of Cylinder | 6 Cylinder in line | |
Aspiration | Turbocharged and Air to Air Aftercooled | |
Governor | Electric | |
Engine Max. Output Power | kW | 450 |
Displacement | L | 13.0 |
Compression Ratio | 17 : 1 | |
Starting Voltage | V | 24 |
Bore | mm | 130 |
Stroke | mm | 163 |
Lubrication Oil Capacity | L | 45.5 |
Intake Air Flow | M3/Min | 28.8 |
Fuel Consumption at 100% Load | L/H | 101 |
Methods to Choose a Suitable and Reliable Generator Manufacturer from China
Model | Standby Power | Prime Power | Engine Model | Dimension Silent Type | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-C22-1 | 22 | 18 | 20 | 16 | 4B3.9-G11 | 2300x 900x1250 | 765 | Download |
A-C22-2 | 22 | 18 | 20 | 16 | 4B3.9-G2 | 2300x 900x1250 | 765 | Download |
A-C28-1 | 28 | 22 | 25 | 20 | 4B3.9-G1 | 2300x 900x1250 | 765 | Download |
A-C28-2 | 28 | 22 | 25 | 20 | 4B3.9-G2 | 2300x 900x1250 | 765 | Download |
A-C44-1 | 44 | 35 | 40 | 32 | 4BT3.9-G1 | 2300x 900x1250 | 770 | Download |
A-C44-2 | 44 | 35 | 40 | 32 | 4BT3.9-G2 | 2300x 900x1250 | 770 | Download |
A-C55 | 55 | 44 | 50 | 40 | 4BT3.9-G2 | 2300x 900x1250 | 780 | Download |
A-C60 | 60 | 50 | 55 | 45 | 4BTA3.9-G2 | 2450x900x1250 | 824 | Download |
A-C72 | 72 | 57 | 65 | 52 | 4BTA3.9-G2 | 2450x900x1250 | 824 | Download |
A-C88 | 88 | 70 | 80 | 63 | 4BTA3.9-G11 | 2450x900x1250 | 980 | Download |
A-C100 | 100 | 77 | 90 | 70 | QSB3.9-G3 | 2450x900x1250 | 980 | Download |
A-C110-1 | 110 | 88 | 100 | 80 | 6BT5.9-G1 | 2900×1080×1500 | 1150 | Download |
A-C110-2 | 110 | 88 | 100 | 80 | 6BT5.9-G2 | 2900×1080×1500 | 1185 | Download |
A-C121 | 121 | 96 | 110 | 87 | 6BT5.9-G2 | 2900×1080×1500 | 1185 | Download |
A-C138 | 138 | 110 | 125 | 100 | 6BTA5.9-G2 | 2900×1080×1500 | 1280 | Download |
A-C150-1 | 150 | 119 | 136 | 109 | QSB5.9-G3 | 3200×1080×1500 | 1350 | Download |
A-C150-2 | 150 | 119 | 136 | 109 | 6BTAA5.9-G2 | 3200×1080×1500 | 1280 | Download |
A-C175 | 175 | 140 | 160 | 127 | 6BTAA5.9-G12 | 3200×1080×1500 | 1300 | Download |
A-C200-1 | 200 | 160 | 182 | 145 | 6CTA8.3-G1 | 3200×1080×1500 | 1600 | Download |
A-C200-2 | 203 | 163 | 185 | 148 | 6CTA8.3-G2 | 3200×1080×1500 | 1550 | Download |
A-C210 | 210 | 167 | 190 | 152 | QSB6.7-G4 | 3500×1126×1700 | 1550 | Download |
A-C220 | 220 | 176 | 200 | 160 | 6CTAA8.3-G2 | 3500×1126×1700 | 1700 | Download |
A-C275-1 | 275 | 220 | 250 | 200 | MTA11-G2A | 3900×1300×1900 | 2750 | Download |
A-C275-2 | 275 | 220 | 250 | 200 | MTA11-G2 | 3900×1300×1900 | 2750 | Download |
A-C275-3 | 275 | 220 | 250 | 200 | NTA855-G1 | 3900×1300×1900 | 3010 | Download |
A-C275-4 | 275 | 220 | 250 | 200 | 6LTAA8.9-G2 | 3500×1126×1700 | 1900 | Download |
A-C286 | 286 | 229 | 260 | 208 | 6LTAA8.9-G3 | 3500×1126×1700 | 2500 | Download |
A-C290 | 290 | 232 | 260 | 208 | QSL8.9-G4 | 3500×1126×1700 | 1900 | Download |
A-C300 | 300 | 240 | 275 | 220 | NTA855-G1A | 3900×1300×1900 | 3010 | Download |
A-C300 | 300 | 240 | 273 | 218 | 6LTAA9.5-G3 | 3500×1126×1700 | 2500 | Download |
A-C344-1 | 344 | 275 | 313 | 250 | MTAA11-G3 | 3900×1300×1900 | 2750 | Download |
A-C350 | 350 | 280 | 313 | 250 | NTA855-G1B | 3900×1300×1900 | 2900 | Download |
A-C344-3 | 344 | 275 | 313 | 250 | NTA855-G2 | 3900×1300×1900 | 2900 | Download |
A-C344-4 | 344 | 275 | 313 | 250 | 6LTAA9.5-G1 | 3500×1126×1700 | 2750 | Download |
A-C375 | 375 | 300 | 341 | 273 | NTA855-G2A | 3900×1300×1900 | 2950 | Download |
A-C385 | 385 | 308 | 350 | 280 | NTA855-G4 | 3900×1300×1900 | 3000 | Download |
A-C408 | 408 | 326 | 370 | 296 | QSZ13-G6 | 3420×1150×2190 | 3140 | Download |
A-C413-1 | 413 | 330 | 375 | 300 | NTAA855-G7 | 3900×1300×1900 | 2800 | Download |
A-C413-2 | 413 | 330 | 375 | 300 | KTA19-G2 | 3580×1277×2065 | 3950 | Download |
A-C413-3 | 413 | 330 | 375 | 300 | 6ZTAA13-G3 | 4350×1450×2180 | 3220 | Download |
A-C424 | 424 | 340 | 385 | 310 | 6ZTAA13-G3 | 4350×1450×2180 | 3220 | Download |
A-C440 | 440 | 352 | 400 | 320 | 6ZTAA13-G3 | 4350×1450×2180 | 3220 | Download |
A-C450 | 450 | 360 | N/A | N/A | NTAA855-G7A | 3000×1050×1780 | 2900 | Download |
A-C456 | 456 | 365 | 415 | 332 | QSZ13-G7 | 3420×1150×2190 | 3140 | Download |
A-C484 | 484 | 387 | 440 | 352 | 6ZTAA13-G2 | 4350×1450×2180 | 3220 | Download |
A-C495-1 | 495 | 396 | 450 | 360 | KTA19-G3 | 4700×1800×2380 | 2900 | Download |
A-C495-2 | 495 | 396 | 450 | 360 | 6ZTAA13-G4 | 4350×1450×2180 | 3220 | Download |
A-C495-3 | 495 | 396 | 450 | 360 | QSZ13-G2 | 4700×1800×2380 | 3220 | Download |
A-C511 | 511 | 409 | 465 | 372 | QSZ13-G5 | 4700×1800×2380 | 3220 | Download |
A-C550-1 | 550 | 440 | 500 | 400 | KTA19-G3A | 4700×1800×2380 | 4250 | Download |
A-C550-2 | 550 | 440 | 500 | 400 | KTA19-G4 | 4700×1800×2380 | 4300 | Download |
A-C560 | 560 | 448 | 510 | 408 | QSZ13-G3 | 4700×1800×2380 | 3220 | Download |
A-C575 | 575 | 462 | 525 | 420 | KTAA19-G5 | 4700×1800×2380 | 4550 | Download |
A-C633 | 633 | 506 | 575 | 460 | KTAA19-G6 | 4700×1800×2380 | 4550 | Download |
A-C650 | 650 | 520 | N/A | N/A | KTA19-G8 | 4700×1800×2380 | 4550 | Download |
A-C688-1 | 688 | 550 | N/A | N/A | KTAA19-G6A | 4700×1800×2380 | 4700 | Download |
A-C688-2 | 687 | 550 | 625 | 500 | KT38-G | 6050×2438×2591 | 6000 | Download |
A-C784 | 784 | 627 | 713 | 570 | KTA38-G1 | 6050×2438×2591 | 6150 | Download |
A-C800 | 800 | 640 | 725 | 580 | KT38-GA | 6050×2438×2591 | 6400 | Download |
A-C825 | 825 | 660 | 750 | 600 | KTA38-G2 | 6050×2438×2591 | 6600 | Download |
A-C880 | 880 | 704 | 800 | 640 | KTA38-G2B | 6050×2438×2591 | 6700 | Download |
A-C1000 | 1000 | 800 | 910 | 728 | KTA38-G2A | 6050×2438×2591 | 6850 | Download |
A-C1100 | 1100 | 880 | 1000 | 800 | KTA38-G5 | 6050×2438×2591 | 7150 | Download |
A-C1250 | 1250 | 1000 | N/A | N/A | KTA38-G9 | 6050×2438×2591 | 7250 | Download |
A-C1375 | 1375 | 1100 | 1250 | 1000 | KTA50-G3 | 12192×2438×2591 | 9140 | Download |
A-C1513 | 1513 | 1210 | 1375 | 1100 | KTA50-G8 | 12192×2438×2591 | 9400 | Download |
A-C1650 | 1650 | 1320 | 1500 | 1200 | KTA50-GS8 | 12192×2438×2591 | 9600 | Download |
Model | Standby Power | Prime Power | Engine Model | Dimension (Silent Type) | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-C28H | 28 | 22 | 25 | 20 | 4B3.9-G11 | 2300x 900x1250 | 765 | Download |
A-C35H | 35 | 28 | 32 | 26 | 4B3.9-G2 | 2300x 900x1250 | 765 | Download |
A-C40H | 40 | 32 | 36 | 29 | 4BT3.9-G12 | 2300x 900x1250 | 770 | Download |
A-C50H | 50 | 40 | 45 | 36 | 4BT3.9-G2 | 2300x 900x1250 | 790 | Download |
A-C60H | 60 | 48 | 55 | 44 | 4BTA3.9-G2 | 2300x 900x1250 | 824 | Download |
A-C75H | 75 | 60 | 68 | 55 | 4BTA3.9-G2 | 2300x 900x1250 | 824 | Download |
A-C100H | 100 | 80 | 90 | 72 | 4BTA3.9-G11 | 2300x 900x1250 | 980 | Download |
A-C125H | 125 | 100 | 114 | 91 | 6BT5.9-G2 | 2900×1080×1500 | 1185 | Download |
A-C150H | 150 | 120 | 136 | 109 | 6BTA5.9-G2 | 2900×1080×1500 | 1185 | Download |
A-C165H | 165 | 132 | 150 | 120 | 6BTAA5.9-G2 | 3200×1080×1500 | 1185 | Download |
A-C188H | 188 | 150 | 170 | 136 | 6BTAA5.9-G12 | 3200×1080×1500 | 1300 | Download |
A-C220H | 220 | 200 | 200 | 160 | 6CTA8.3-G2 | 3200×1080×1500 | 1550 | Download |
A-C250H | 250 | 200 | 227 | 182 | 6CTAA8.3-G2 | 3500×1140×1700 | 1700 | Download |
A-C275H | 275 | 220 | N/A | N/A | NT855-GA | 3900×1300×1900 | 2800 | Download |
A-C300H | 300 | 240 | 273 | 218 | 6LTAA8.9-G2 | 3500×1140×1700 | 2200 | Download |
A-C344H | 344 | 275 | 313 | 250 | NTA855-G1 | 3900×1300×1900 | 2900 | Download |
A-C316H | 316 | 253 | 288 | 230 | 6LTAA8.9-G3 | 3500×1140×1700 | 2250 | Download |
A-C330H | 330 | 264 | 300 | 240 | 6LTAA9.5-G3 | 3500×1126×1700 | 2500 | Download |
A-C375H | 375 | 300 | 344 | 275 | NTA855-G1B | 3900×1300×1900 | 2950 | Download |
A-C375H-1 | 375 | 300 | 344 | 275 | NTA855-G2 | 3900×1300×1900 | 2950 | Download |
A-C347H | 347 | 277 | 315 | 252 | 6LTAA9.5-G1 | 3500×1126×1700 | 2640 | Download |
A-C438H | 438 | 350 | 398 | 318 | NTA855-G3 | 3900×1300×1900 | 2950 | Download |
A-C424H | 424 | 339 | 386 | 309 | 6ZTAA13-G3 | 3500×1126×1700 | 3220 | Download |
A-C445H | 445 | 356 | 405 | 324 | QSZ13-G6 | 4700×1800×2380 | 3140 | Download |
A-C500H | 500 | 400 | 455 | 364 | KTA19-G2 | 4700×1800×2380 | 2900 | Download |
A-C480H | 480 | 384 | 436 | 349 | 6ZTAA13-G2 | 3500×1126×1700 | 3220 | Download |
A-C500H | 500 | 400 | 455 | 364 | 6ZTAA13-G4 | 3500×1126×1700 | 3220 | Download |
A-C500H-1 | 500 | 400 | 455 | 364 | QSZ13-G2 | 4700×1800×2380 | 3220 | Download |
A-C511H | 511 | 409 | 465 | 372 | QSZ13-G7 | 4700×1800×2380 | 3220 | Download |
A-C560H | 560 | 448 | 509 | 407 | KTA19-G3 | 4700×1800×2380 | 2900 | Download |
A-C550H | 550 | 440 | 500 | 400 | QSZ13-G5 | 4700×1800×2380 | 3220 | Download |
A-C530H | 530 | 424 | 482 | 386 | QSZ13-G3 | 4700×1800×2380 | 3220 | Download |
A-C625H | 625 | 500 | 568 | 455 | KTA19-G3A | 4700×1800×2380 | 4250 | Download |
A-C625H-1 | 625 | 500 | 568 | 455 | KTA19-G4 | 4700×1800×2380 | 4300 | Download |
A-C660H | 660 | 528 | 600 | 480 | KTAA19-G5 | 4700×1800×2380 | 4550 | Download |
A-C750H | 750 | 600 | N/A | N/A | KTAA19-G6A | 4700×1800×2380 | 4550 | Download |
A-C850H | 850 | 680 | 775 | 620 | KT38-G | 6050×2438×2591 | 6000 | Download |
A-C963H | 963 | 770 | 875 | 700 | KTA38-G1 | 6050×2438×2591 | 6150 | Download |
A-C1000H | 1000 | 800 | 909 | 727 | KTA38-G2 | 6050×2438×2591 | 6600 | Download |
A-C1031H | 1031 | 825 | 938 | 750 | KTA38-G2B | 6050×2438×2591 | 6700 | Download |
A-C1100H | 1100 | 880 | 1000 | 800 | KTA38-G2A | 6050×2438×2591 | 6850 | Download |
A-C1250H | 1250 | 1000 | 1136 | 909 | KTA38-G4 | 6050×2438×2591 | 7150 | Download |
A-C1525H | 1525 | 1220 | N/A | N/A | KTA38-G9 | 6050×2438×2591 | 7250 | Download |
A-C1513H | 1513 | 1210 | 1375 | 1100 | KTA50-G3 | 12192×2438×2591 | 9140 | Download |
A-C1733H | 1733 | 1386 | 1575 | 1260 | KTA50-G9 | 12192×2438×2591 | 9400 | Download |
ATS
ATS cabinet is mainly applied to the automatic switch between prime and emergency power, composing an automatic emergency power supply system together with diesel generating sets. It will monitor prime power, When it is cut off, it can automatically switch loads such as emergency illumination, security power and fire fighting equipment to generating sets. Auto start, auto transfer, auto protection, auto power supply
Standard configuration:
Brand: ABB, Schneider, Socome, Suyang, AISIKAI
PARALLEL DISTRIBUTION CABINET
Parallel distribution cabinet is designed for the parallel running of main power diesel generator sets. The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.
Load Bank
The purpose of most land banks is used to test of the emergency generator sets, verifying all genset components are in optimal working condition under different loads. Another purpose is working combined with the generator set, to take the load of the generator set is always above 30%
Advantages of Load Bank
Four types of load banks are usually used to genset.