Tel : +86-591-86397381
Email : sale@hosempower.com
Skype : +86-13205904365
Power Output: 800 kilovolt-amperes (KVA)
Engine: Perkins diesel engine, 4006-23TAG3A
Alternator: High-quality brushless alternator, Stamford and Leroy Somer for alternative.
Control Panel: Deepsea/ ComAp/ Smartgen
Fuel System: Reliable fuel system with substantial tank capacity
Noise Reduction: Soundproofed, 80db @ 7 mether
Safety Features: Automatic shutdown mechanisms for critical conditions
Remote Monitoring and Control: Optional remote monitoring and control capabilities
Item no.:
A-P880Payment:
TT/LCProduct origin:
ChinaLead Time:
30-35 daysFeatures:
Maintenance and Service: Perkins generators are supported by a comprehensive network of service providers and authorized dealers who offer maintenance, servicing, and spare parts. Regular maintenance and timely servicing are crucial for optimal performance and longevity of the generator.
Safety Features: The Perkins Generator 825KVA is equipped with various safety features to protect the generator, users, and connected electrical systems. These features may include automatic shutdown mechanisms for low oil pressure, high temperature, and other critical conditions, ensuring the safety of the generator and preventing potential damage.
Remote Monitoring and Control: Some Perkins generators offer the option of remote monitoring and control capabilities. This allows users to conveniently monitor the generator's performance, fuel levels, and other parameters remotely, enhancing convenience and control over the power supply.
Application Versatility: Perkins generators are versatile and suitable for a wide range of applications, including construction sites, industrial facilities, commercial buildings, events, and more. They can provide reliable power backup during outages or serve as the primary source of electricity in remote locations.
Environmental Considerations: Perkins generators are designed with environmental sustainability in mind. They comply with emission regulations and strive to reduce their carbon footprint. Depending on the model, Perkins generators may incorporate advanced technologies like exhaust aftertreatment systems to minimize emissions and ensure environmental compliance.
Reliable Power Solution: With its robust engine, efficient alternator, and durable construction, the Perkins Generator 825KVA offers a reliable power solution for various power needs. It provides a stable and continuous power supply, ensuring smooth operation of equipment and systems.
Choosing a Perkins Generator: When selecting a Perkins generator, it is essential to consider the specific power requirements, application needs, and any additional features or customization options. Consulting with a trusted generator supplier or authorized dealer can help determine the most suitable Perkins generator for your specific needs.
Invest in a Perkins Generator: With its proven track record, reputable brand, and reliable performance, investing in a Perkins Generator ensures a dependable power solution that meets the demands of your business or project. Whether for standby power, prime power, or continuous power, a Perkins Generator delivers the performance and peace of mind you need.
Why Choose Hosem Power?
1. Hosem Power engaged in the generator area for 15 years, we have rich experience in R&D and manufacturing generator sets.
2. Every generator will be tested strictly before shipment, including:
1) Parts faults testing
2) Fuel tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insulation testing
6) Noise testing
7) Loading Testing: 25%, 50%, 75%, 100%, 110% load to check verify that all control systems, alarm and shut-down protection.
3. production is submitted to ISO8528 and CE certification, and quality is certified by ISO9001 Management System to guarantee high-quality products and service.
FAQ
Q: What is a Perkins generator?
A: A Perkins generator refers to a generator set that is powered by a Perkins diesel engine. Perkins is a renowned manufacturer of reliable and efficient engines used in various industries, including power generation.
Q: What power output range is available for Perkins generators?
A: Perkins generators are available in a wide range of power outputs, from small portable units to large industrial generators. The power output can vary from a few kilovolt-amperes (KVA) to several megawatts (MW), depending on the specific model and application.
Q: What are the benefits of choosing a Perkins generator?
A: Perkins generators offer several benefits, including excellent fuel efficiency, reliable performance, low operating costs, and durability. Perkins engines are known for their robust construction, long service life, and ability to perform well even in harsh operating conditions.
Q: Are Perkins generators suitable for both standby and prime power applications?
A: Yes, Perkins generators are designed to serve both standby and prime power applications. Standby generators are used as backup power sources during utility outages, while prime power generators provide continuous power for extended periods.
Q: Can Perkins generators be used in various industries?
A: Yes, Perkins generators find applications in diverse industries such as construction, healthcare, telecommunications, manufacturing, agriculture, and more. They can power critical equipment, facilities, and processes in different sectors.
Q: Do Perkins generators comply with emission regulations?
A: Yes, Perkins engines used in generators comply with global emission regulations, such as those set by the Environmental Protection Agency (EPA) and the European Union (EU). They incorporate advanced technologies to reduce emissions and meet environmental standards.
Q: How often should Perkins generators undergo maintenance?
A: Regular maintenance is essential to ensure optimal performance and prolong the lifespan of Perkins generators. The maintenance intervals may vary based on factors such as operating hours, environmental conditions, and the specific model. It is recommended to follow the maintenance schedule outlined in the generator's user manual or consult with a qualified service provider.
Q: Can Perkins generators be synchronized and paralleled?
A: Yes, Perkins generators can be synchronized and paralleled to increase power output or achieve redundancy in larger installations. Synchronization and paralleling allow multiple generators to work together seamlessly, providing greater flexibility and reliability in power supply.
Q: Where can I get support and service for my Perkins generator?
A: Perkins has an extensive network of authorized service providers and distributors worldwide. They offer technical support, spare parts, and maintenance services for Perkins generators. You can contact your local Perkins dealer or visit their website for assistance.
Q: Are Perkins generators backed by warranty?
A: Yes, Perkins generators typically come with a manufacturer's warranty that covers the engine and generator components. The warranty duration may vary depending on the model and region. It is important to review the warranty terms and conditions provided by the manufacturer.
Model | Standby Power | Prime Power | Engine Model | Dimension | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-P10-1 | 10 | 8 | 9 | 7 | 403A-11 G1 | 1950×800×1115 | 560 | Download |
A-P10-2 | 10 | 8 | 9 | 7 | 403D-11G | 1950×800×1115 | 560 | Download |
A-P14-1 | 14 | 11 | 13 | 10 | 403A-15G1 | 1950×800×1115 | 700 | Download |
A-P14-2 | 14 | 11 | 13 | 10 | 403D-15G | 1950×800×1215 | 700 | Download |
A-P15 | 16 | 13 | 15 | 12 | 403A-15G2 | 1950×800×1215 | 760 | Download |
A-P22-1 | 22 | 18 | 20 | 16 | 404A-22G1 | 2100×740×1115 | 740 | Download |
A-P22-2 | 22 | 18 | 20 | 16 | 404D-22G | 2100×740×1115 | 740 | Download |
A-P30 | 30 | 24 | 27 | 22 | 404D-22TG | 2300×980×1270 | 780 | Download |
A-P32 | 32 | 26 | 30 | 24 | 1103A-33G | 2300×980×1270 | 1250 | Download |
A-P50 | 50 | 40 | 45 | 36 | 1103A-33TG1 | 2600×1130×1540 | 1360 | Download |
A-P66 | 66 | 53 | 60 | 48 | 1103A-33TG2 | 2600×1130×1540 | 1580 | Download |
A-P72 | 72 | 57 | 65 | 52 | 1104A-44TG1 | 2800×1130×1560 | 1580 | Download |
A-P88-1 | 88 | 70 | 80 | 64 | 1104A-44TG2 | 2800×1130×1560 | 1580 | Download |
A-P88-2 | 88 | 70 | 80 | 64 | 1104C-44TAG1 | 2800×1130×1560 | 1600 | Download |
A-P110 | 110 | 88 | 100 | 80 | 1104C-44TAG2 | 2800×1130×1560 | 1720 | Download |
A-P150 | 150 | 120 | 135 | 108 | 1106A-70TG1 | 3200×1130×1715 | 2215 | Download |
A-P165 | 165 | 132 | 150 | 120 | 1106A-70TAG2 | 3600×1130×2105 | 2215 | Download |
A-P200 | 200 | 160 | 180 | 144 | 1106A-70TAG3 | 3600×1130×2105 | 2385 | Download |
A-P220 | 220 | 176 | 200 | 160 | 1106A-70TAG4 | 3600×1130×2105 | 2450 | Download |
A-P254 | 254 | 203 | 231 | 185 | 1506A-E88TAG2 | 4000×1422×2190 | 3485 | Download |
A-P283 | 283 | 226 | 257 | 206 | 1506A-E88TAG3 | 4000×1422×2190 | 3485 | Download |
A-P338 | 338 | 270 | 307 | 246 | 1506A-E88TAG5 | 4000×1422×2190 | 3625 | Download |
A-P400 | 400 | 320 | 350 | 280 | 2206C-E13TAG2 | 4400×1422×2450 | 4290 | Download |
A-P450 | 450 | 360 | 400 | 320 | 2206C-E13TAG3 | 4400×1422×2450 | 4290 | Download |
A-P500 | 500 | 400 | 455 | 364 | 2506C-E15TAG1 | 4600×1422×2530 | 5070 | Download |
A-P550 | 550 | 440 | 500 | 400 | 2506C-E 15TAG2 | 4600×1422×2530 | 5070 | Download |
A-P650 | 650 | 520 | 591 | 473 | 2806C-E 18TAG 1A | 4800×1822×2522 | 6000 | Download |
A-P700 | 700 | 560 | 650 | 520 | 2806A-E18TAG2 | 4800×1822×2522 | 6050 | Download |
A-P820 | 820 | 656 | 746 | 597 | 4006-23TAG2A | 6059×2438×2591 | 8250 | Download |
A-P880 | 880 | 704 | 800 | 640 | 4006-23TAG3A | 6059×2438×2591 | 8250 | Download |
A-P1000 | 1000 | 800 | 910 | 728 | 4008TAG1A | 6059×2438×2591 | 9820 | Download |
A-P1125-1 | 1125 | 900 | 1022 | 818 | 4008TAG2A | 6059×2438×2591 | 9820 | Download |
A-P1125-2 | 1125 | 900 | 1022 | 818 | 4008TAG2 | 6059×2438×2591 | 9820 | Download |
A-P1250 | 1250 | 1000 | 1125 | 900 | 4008-30TAG3 | 6059×2438×2591 | 9820 | Download |
A-P1375-1 | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2A | 12192x2438x2896 | 12900 | Download |
A-P1375-2 | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2 | 12192x2438x2896 | 12900 | Download |
A-P1500 | 1500 | 1200 | 1375 | 1100 | 4012-46TWG3A | 12192x2438x2896 | 13000 | Download |
A-P1650 | 1650 | 1320 | 1500 | 1200 | 4012-46TAG2A | 12192x2438x2896 | 13000 | Download |
A-P1850 | 1850 | 1480 | 1688 | 1350 | 4012-46TAG3A | 12192x2438x2896 | 13000 | Download |
A-P2000 | 2000 | 1600 | 1850 | 1480 | 4016TAG1A | 12192x2438x2896 | 16100 | Download |
A-P2200-1 | 2200 | 1760 | 2000 | 1600 | 4016TAG2A | 12192x2438x2896 | 16100 | Download |
A-P2200-2 | 2200 | 1760 | 2000 | 1600 | 4016-61TRG2 | 12192x2438x2896 | 16100 | Download |
A-P2500 | 2500 | 2000 | 2250 | 1800 | 4016-61TRG3 | 12192x2438x2896 | 16200 | Download |
Model | Standby Power | Prime Power | Engine Model | Dimension | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-P13H | 13 | 10 | 11 | 9 | 403D-11G | 1950×800×1115 | 560 | Download |
A-P16H | 16 | 13 | 15 | 12 | 403D-15G | 1950×800×1215 | 700 | Download |
A-P19H | 19 | 15 | 17 | 14 | 403A-15G2 | 1950×800×1215 | 760 | Download |
A-P226H | 26 | 21 | 24 | 19 | 404D-22G | 2100×740×1115 | 740 | Download |
A-P35H | 35 | 29 | 33 | 26 | 404D-22TG | 2100×740×1115 | 740 | Download |
A-P38H | 38 | 30 | 35 | 28 | 1103A-33G | 2300×980×1270 | 1250 | Download |
A-P59H | 59 | 47 | 54 | 43 | 1103A-33TG1 | 2600×1130×1540 | 1360 | Download |
A-P75H | 75 | 60 | 68 | 55 | 1103A-33TG2 | 2600×1130×1540 | 1580 | Download |
A-P84H | 84 | 67 | 76 | 61 | 1104A-44TG1 | 2800×1130×1560 | 1580 | Download |
A-P100H-1 | 100 | 80 | 90 | 73 | 1104A-44TG2 | 2800×1130×1560 | 1580 | Download |
A-P100H-2 | 100 | 80 | 90 | 72 | 1104C-44TAG1 | 2800×1130×1560 | 1600 | Download |
A-P125H | 125 | 100 | 115 | 92 | 1104C-44TAG2 | 2800×1130×1560 | 1720 | Download |
A-P169H | 169 | 135 | 152 | 122 | 1106A-70TG1 | 3200×1130×1715 | 2215 | Download |
A-P188H | 188 | 150 | 169 | 135 | 1106A-70TAG2 | 3600×1130×2105 | 2215 | Download |
A-P219H | 219 | 175 | 197 | 158 | 1106A-70TAG3 | 3600×1130×2105 | 2385 | Download |
A-P273H | 273 | 218 | 248 | 198 | 1506A-E88TAG2 | 4000×1422×2190 | 3485 | Download |
A-P320H | 320 | 256 | 290 | 232 | 1506A-E88TAG3 | 4000×1422×2190 | 3485 | Download |
A-P390H | 390 | 312 | 352 | 282 | 1506A-E88TAG5 | 4000×1422×2190 | 3625 | Download |
A-P438H-1 | 438 | 350 | 400 | 320 | 2206C-E13TAG2 | 4400×1422×2450 | 4290 | Download |
A-P438H-2 | 438 | 350 | 400 | 320 | 2206C-E13TAG3 | 4400×1422×2450 | 4290 | Download |
A-P563H-1 | 563 | 450 | 500 | 400 | 2506C-E15TAG1 | 4600×1422×2530 | 5070 | Download |
A-P563H-2 | 563 | 450 | 500 | 400 | 2506C-E 15TAG2 | 4600×1422×2530 | 5070 | Download |
A-P687H-1 | 687 | 550 | 625 | 500 | 2806C-E 18TAG 1A | 4800×1822×2522 | 6000 | Download |
A-P687H-2 | 687 | 550 | 625 | 500 | 2806A-E18TAG2 | 4800×1822×2522 | 6000 | Download |
A-P825H | 825 | 660 | 750 | 600 | 4006-23TAG2A | 6059×2438×2591 | 8250 | Download |
A-P940H | 940 | 750 | 849 | 679 | 4006-23TAG3A | 6059×2438×2591 | 8250 | Download |
A-P1100H | 1100 | 880 | 1000 | 800 | 4008TAG2 | 6059×2438×2591 | 9820 | Download |
A-P1375H | 1375 | 1100 | 1250 | 1000 | 4012-46TWG2A | 12192x2438x2896 | 12900 | Download |
A-P1500H | 1500 | 1200 | 1375 | 1100 | 4012-46TWG3A | 12192x2438x2896 | 13000 | Download |
A-P1650H | 1650 | 1320 | 1500 | 1200 | 4012-46TAG2A | 12192x2438x2896 | 13000 | Download |
A-P1850H | 1850 | 1480 | 1690 | 1350 | 4012-46TAG3A | 12192x2438x2896 | 13000 | Download |
ATS
ATS cabinet is mainly applied to the automatic switch between prime and emergency power, composing an automatic emergency power supply system together with diesel generating sets. It will monitor prime power, When it is cut off, it can automatically switch loads such as emergency illumination, security power and fire fighting equipment to generating sets. Auto start, auto transfer, auto protection, auto power supply
Standard configuration:
Brand: ABB, Schneider, Socome, Suyang, AISIKAI
PARALLEL DISTRIBUTION CABINET
Parallel distribution cabinet is designed for the parallel running of main power diesel generator sets. The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.
Load Bank
The purpose of most land banks is used to test of the emergency generator sets, verifying all genset components are in optimal working condition under different loads. Another purpose is working combined with the generator set, to take the load of the generator set is always above 30%
Advantages of Load Bank
Three types of load banks are usually used to genset.
Tags :