Tel : +86-591-86397381
Email : sale@hosempower.com
Skype : +86-13205904365
Powered by Isuzu, low fuel consuption and Fuel-efficient
Complete generator with ISO and CE certificate
Range 20KVA-110KVA, perfect performance on power continuous output, emission control, fuel consumption cost, vibration etc.
The controller has complete functions. If high temperature, high speed, overload, etc. occur, the generator set will automatically stop working to ensure that you can use it safely.
8 hours working time fuel tank, solve your problem of frequent refueling
How to Calculate the Generator Fuel Consumption?
The formula to calculate diesel generator fuel consumption is:
Where:
- Fuel Consumption (L/h) is the amount of diesel fuel consumed per hour by the generator (in liters).
- Generator Output (kW) is the power output of the generator (in kilowatts).
- Fuel Consumption (g/kWh) is the fuel consumption rate of the engine, typically provided in grams per kilowatt-hour.
- Density of Diesel (g/mL) is the density of diesel fuel, usually around 0.85 to 0.86 grams per milliliter.
How can we optimize the fuel consumption efficiency of our generators?
fuel consumption is essential for optimal generator performance. To reduce fuel usage and ensure your generator operates at its best, consider these steps:
1. Regular Maintenance: Professional servicing by experts is crucial to keep your generator in top condition. Regular maintenance can identify and fix issues that cause stress on the generator, leading to increased fuel consumption. Using genuine spare parts from reliable suppliers during repairs is vital to maintain the generator's integrity.
2. Carbon Deposits Removal: Over time, carbon deposits can accumulate on various engine components, affecting combustion efficiency. This buildup often results in increased fuel consumption and black smoke emissions. Cleaning these components with gentle chemical detergents or manual washing can significantly reduce fuel usage. Follow the manufacturer's guidelines or seek advice from professionals for proper cleaning techniques.
3. Coolant Temperature Maintenance: Correct coolant temperature is vital for efficient generator operation. Diesel generators use water as a coolant, and maintaining the right temperature is essential for proper engine cooling. Incorrect temperatures can lead to incomplete combustion, ultimately increasing fuel consumption. Regularly monitor and maintain the coolant temperature to ensure optimal generator performance."
Contact us right now if you want to know more about our low fuel consumption generators.
Why Choose Hosem Power?
1. Hosem Power engaged in the generator area for 15 years, we have rich experience in R&D and manufacturing generator sets.
2. Every generator will be tested strictly before shipment, including:
3. production is submitted to ISO8528 and CE certification, and quality is certified by ISO9001 Management System to guarantee high-quality products and service.
FAQ
Q: What's your warranty?
A: All our products we offer one year warranty or 1000 hours which comes first.
Q: What's your delivery time?
A: Standard product 20 days - 35 days. Customized product 40 days.
Q: Can we add our logo to products?
A: Yes, there are several ways to do this. We can put the label of your logo on the products or make the silk print of your logo on the products. It is free.
Q: Can we customize the product?
A: We have a very experienced technical team, we can customize any product according to your requirements, such as synchronization system, wet exhaust system, ultra-silent system
Q: What certifications are for your gen sets?
A: ISO9001-2008, ISO14001-2004, CE, SASO, SONCAP, RETIE, etc.
Model | Standby Power | Prime Power | Engine Model | Dimension | Weight | Datasheet | ||
kVA | kW | kVA | kW | LXWXH(MM) | KG | |||
A-I17 | 15 | 12 | 17 | 13 | 4JA1-D1 | 2008x900x1130 | 570 | Download |
A-I22 | 20 | 16 | 22 | 18 | 4JA1-F1 | 2008x900x1130 | 580 | Download |
A-I28 | 25 | 20 | 28 | 22 | 4JA1-Z1 | 2008x900x1130 | 630 | Download |
A-I28 | 25 | 20 | 28 | 22 | 4JB1 | 2188x900x1280 | 630 | Download |
A-I33 | 30 | 24 | 33 | 26 | 4JB1T | 2188x900x1280 | 640 | Download |
A-I41 | 38 | 30 | 41 | 33 | 4JB1TA | 2188x900x1280 | 640 | Download |
A-I41 | 38 | 30 | 41 | 33 | 4JB1TA | 2188x900x1280 | 655 | Download |
A-I55 | 50 | 40 | 55 | 44 | 4JB1T-S | 2188x900x1280 | 675 | Download |
A-I55 | 50 | 40 | 55 | 44 | 4BD1-Z | 2388x1000x1450 | 700 | Download |
A-I69 | 63 | 50 | 69 | 55 | 4BG1-Z | 2388x1000x1450 | 860 | Download |
A-I110 | 100 | 80 | 110 | 88 | 6BG1-Z1 | 3288x1130x1850 | 1250 | Download |
A-I125 | 113 | 90 | 125 | 100 | 6BG1-ZL1 | 3288x1130x1850 | 1340 | Download |
A-I22 | 22 | 18 | 20 | 16 | JE493DB-04 | 2188x900x1280 | 620 | Download |
A-I28 | 28 | 22 | 25 | 20 | JE493DB-02 | 2188x900x1280 | 640 | Download |
A-I33 | 33 | 26 | 30 | 24 | JE493ZDB-04 | 2188x900x1280 | 670 | Download |
A-I44 | 44 | 35 | 40 | 32 | JE493ZLDB-02 | 2188x900x1280 | 690 | Download |
Model | Standby Power | Prime Power | Engine Model | Dimension (Silent Type) | Weight | Datasheet | ||
kVA | kVA | LXWXH(MM) | KG | |||||
A-I22H | 22 | 18 | 20 | 16 | 4JA1-D1 | 2008x900x1130 | 580 | Download |
A-I28H | 28 | 22 | 25 | 20 | 4JA1-F1 | 2008x900x1130 | 590 | Download |
A-I30H | 30 | 24 | 28 | 22 | 4JB1 | 2008x900x1130 | 630 | Download |
A-I33H | 33 | 26 | 30 | 24 | 4JA1-Z1 | 2008x900x1130 | 645 | Download |
A-I38H | 38 | 30 | 33 | 26 | 4JB1T | 2188x900x1280 | 675 | Download |
A-I48H | 48 | 39 | 44 | 35 | 4JB1TA | 2188x900x1280 | 690 | Download |
A-I62H | 62 | 50 | 56 | 45 | 4JB1T-S | 2188x900x1280 | 780 | Download |
A-I62H | 62 | 50 | 56 | 45 | 4BD1-Z | 2388x1000x1450 | 780 | Download |
A-I76H | 76 | 61 | 69 | 55 | 4BG1-Z | 2388x1000x1450 | 880 | Download |
A-I128H | 128 | 102 | 116 | 93 | 6BG1-Z1 | 3288x1130x1850 | 1200 | Download |
A-I138H | 138 | 110 | 125 | 100 | 6BG1-ZL1 | 3288x1130x1850 | 1360 | Download |
A-I28H | 28 | 22 | 25 | 20 | JE493DB-03 | 2188x900x1280 | 630 | Download |
A-I33H | 33 | 26 | 30 | 24 | JE493DB-01 | 2188x900x1280 | 655 | Download |
A-I41H | 41 | 33 | 38 | 30 | JE493ZDB-03 | 2188x900x1280 | 660 | Download |
A-I55H | 55 | 44 | 50 | 40 | JE493ZLDB-01 | 2188x900x1280 | 700 | Download |
ATS
ATS cabinet is mainly applied to the automatic switch between prime and emergency power, composing an automatic emergency power supply system together with diesel generating sets. It will monitor prime power, When it is cut off, it can automatically switch loads such as emergency illumination, security power and fire fighting equipment to generating sets. Auto start, auto transfer, auto protection, auto power supply
Standard configuration:
Brand: ABB, Schneider, Socome, Suyang, AISIKAI
PARALLEL DISTRIBUTION CABINET
Parallel distribution cabinet is designed for the parallel running of main power diesel generator sets. The system can operate automatically or be controlled manually.
The system has the functions of automatic frequency detection, synchronizing detection and switch-on.
It is convenient to expand the capacity to satisfy the need of increasing load.
It can be used together with multiple generating sets (32 parallel generating sets max.) to control multiple diesel generating sets for automatic synchronization.
It offers stable frequency and voltage and can bear large-capacity load impact, achieving reliable supply, centralized management and more flexible power allocation.
Load Bank
The purpose of most land banks is used to test of the emergency generator sets, verifying all genset components are in optimal working condition under different loads. Another purpose is working combined with the generator set, to take the load of the generator set is always above 30%
Advantages of Load Bank
Three types of load banks are usually used to genset.
Tags :